Air time
Web site compiles top 10 air system mistakes
by Dan Wise
Compressorwise.com has had the privilege of meeting and interviewing
hundreds of individuals involved with compressed air systems.
The experience gave us an insight into the problem
areas common to most air systems.
We hope this report will give
you some ideas for making
improvements in your plant.
Mistake 1: Believing
compressed air is cheap
Air compressors powered by electrical motors will use a
surprisingly large amount of energy each and every year of
operation. The annual power cost to operate a compressor
can equal the initial cost of the unit.
The initial purchase price of a 100-horsepower air
compressor ranges between $30,000 and $50,000, depending
on the type and options. The same 100-horsepower compressor
operating 6,000 hours a year (a power rate of 7 cents per
kilowatt and
a motor efficiency of .90) will have an annual power cost of
$34,800.
You can determine the annual
electric power cost of your
compressors with this formula. The first step is to
multiply the horsepower of the compressor times .746 times
the hours of operation times your power rate (HP x .746 x
hours x power rate). Then, divide that number by the motor
efficiency.
Everyone in the plant should be aware of the total
power cost for operating the compressors. This is
especially important for anyone working with air operated
equipment.
Mistake 2: Air leaks
The most common opportunity to recover energy cost is to
control the compressed air leaks.
Effective leak control in an air system can pay huge
dividends. A one-quarter inch leak in a 100 psi system will
pass about
100 CFM of compressed air. This is approximately $12,000 in
annual wasted power cost based on 24 hours a day compressor
operation with a power rate of 7 cents per kilowatt.
The process of detecting and monitoring leaks should focus
on more than the basic header and piping system. The fact
is that you will find a majority of your leaks at valves,
fittings, connections, tools and at the point of use.
It is important to remember
the interdependent relationship
between air system components. Controlling air leaks will
not translate into reduced energy cost unless the
compressor
controls and air delivery system are in proper working
condition.
Mistake 3: Compressor
controls
There are several types of control systems in operation for
reciprocating, rotary screw and centrifugal compressors. It's common to
find a variety of these in use in the same plant.
Compressor controls make it
possible for you to translate
lower air usage into lower energy cost. However, the
typical plant is operating multiple compressors at part
load,
which is inefficient and expensive.
Mistake 4: Pressure loss in piping system
It's important to minimize pressure drop throughout the
compressed air system. This prevents you from producing
pressure that never reaches the demand point, which is a
direct waste of energy.
Every pound of increase or
decrease in pressure requires one half of one percent increase or decrease in
power. Therefore, a 10 psig
decrease can save you 5 percent in power costs.
This amounts to $1,740 in annual savings for the 100-horsepower compressor
in the earlier example. This adds up because most
industrial plants have
more than one 100-horsepower compressor.
The pressure of an air system is often raised to overcome
pressure drop. The cause is usually found to be
shortcomings in the piping system and pressure loss at the
filters and dryers. Each of these problem areas will cost
you money on an annual basis.
The following are some common problem areas:
a) Delivering air to the point of use in pipe that is too
small. An example: using 30 feet or more of 3/8-inch rubber
hose
rather than 1-inch pipe with a short hose at the tool.
b) Using "tee" pipe connections rather than 30- or 45-degree
angle entry connections when introducing air into a flowing
stream of air.
c) Saving money by using undersized filters and dryers that
have a higher pressure drop.
Mistake 5: Contamination
from piping system
The following are two common mistakes made during the
installation of the piping system.
a) Dirt, rust and liquids are commonly found in the piping
of a compressed air system. These cause maintenance and
interrupt the supply of air.
The amount of these
contaminants that are carried along with
the air stream will increase when the air velocity
increases. Air velocity increases as the pipe size goes
down.
It's acceptable for the interconnecting pipe (from compressors, dryers and
inline filters to main header) and
main air header pipe to have a different air velocity
specification than the piping from the main header to the
points of air usage.
The interconnecting pipe and
main header should have an air
velocity between 20 and 30 feet per second (not to exceed 30
feet per second). The air lines running to the points of
air usage should not exceed 50 feet per second.
You can calculate the air velocity of your system. The
formula is: flow in CFM divided by compression ratio in the
pipe divided by the area of pipe divided by 60. This will
give you the velocity in feet per second.
b) The piping system should
always take the air off the top
of an air line when running a line from a header to the
point of air usage. This will prevent condensation and
trash from migrating to the air usage equipment.
Mistake 6: Poor condensation management
Condensation is the moisture that drops out of an air flow
as it cools. The condensation in a compressed air system is
a constant threat to cause expensive problems. The
following are a few examples:
a) Moisture washes
lubrication from air tools and
production equipment causing downtime and maintenance.
b) An inconsistent supply of dry air causes production
quality problems.
c) Excessive rust and scale
often forms in the air
distribution system.
d) Water can back up into the compressor and wreck the
machinery.
e) Air dryers can become
overloaded.
f) In-line filters can be
destroyed.
The problems get worse if you
operate lubed reciprocating or
oil-flooded rotary screw compressors, which is just about
everyone. Compressor oil makes its way into the
distribution system with the compressed air. The mixture of
oil, water, dirt and heat tends to build up a sludge that
will ultimately jam or clog production equipment, air tools
and drains.
The situation is further
complicated by climate and seasonal
weather changes. This is because the amount of condensation
generated will change according to changes in the
temperature and the relative humidity of the inlet air.
Consider that a 200-horsepower compressor operating in a
climate of 60 degrees F with 40 percent relative humidity
will
generate approximately 50 gallons of condensate a day.
However, that same compressor operating in a climate of 90
degrees F with 70 percent relative humidity will generate
approximately 260 gallons of condensate a day.
The typical compressed air system is designed to remove
condensation at strategic locations. This means there are
drains at the aftercooler separator, receiver tank, air
dryer, in-line filters and at drain points in the piping.
The problem is that there are
shortcomings with the products
being used to drain the condensation. A condensation drain
should automatically remove condensate when it appears at
the drain without wasting air or clogging.
We have found only one drain that meets this criteria. If
you want details, send an email to drain@compressorwise.com
with your mailing address. We will have the appropriate
information sent to your attention.
Mistake 7: Supplying higher pressure air than is needed
The first consideration is to determine the specific
pressure required for all the air requirements in your
plant. Plants that have studied this issue often found that
they were producing high-pressure air for the entire plant
just to satisfy an isolated high pressure requirement.
They solved this problem by installing a small, departmental
compressor designed to handle the higher pressure. This
allowed them to lower the pressure requirement of the main
compressors and immediately save energy cost.
Mistake 8: A lack of air
system training
The operation and management of a compressed air system
takes the efforts and talents of many people. A decision to
work toward energy savings will require all of these
individuals to be part of the process. However, they can
not be effective if they don't understand the cost of
compressed air and the interdependency of the components of
an air system.
The companies that have
trained their people on the
importance of saving energy have reaped the biggest savings. This type of
training has a very fast payback.
The energy savings will go
directly to the bottom line and
can make a difference in the profitability of any company. Send an email to
training@compressorwise.com
for our recommended training.
Mistake 9: Lack of trouble
shooting information
Temperature and pressure readings can organize your troubleshooting efforts
when dealing with a problem in the
compressed air system. Specifically, you can use normal
condition readings as a reference point in order to isolate
the cause of the problem.
The normal condition readings
are taken on a regular basis
for historical reference and to observe any trends that
indicate the beginning of a problem. The readings are
usually taken at locations before and after air equipment
including, among others, the compressors, aftercoolers,
dryers, receivers, air tools and filters.
a) Increasing temperature in a compressed air system is one
of the best indicators of a problem. If you monitor
temperatures over time, you can build a base line for normal
conditions and create a model for predicting when you will
have trouble with your compressed air equipment.
The most useful tool for this application is an infrared
thermometer. This is a handheld device that gathers
temperature readings by aiming at an object.
There are a couple of points to keep in mind on this issue.
The first is to be aware that you are measuring the surface
temperature, not the temperature of the oil, air or water
inside the object.
This method is not as accurate as putting a probe in the
oil, air or water. However, it is a practical way to get
information that can be used in troubleshooting.
The second point is to always take temperature readings when the compressor is
at full load. This gives you meaningful
information that can be compared to the design standards for
the equipment.
The infrared thermometers manufactured by Raytek Corporation
are considered among the best products in this industry.
That company has a
range of products that can handle most
applications.
b) Monitoring pressure is
another useful trouble shooting
tool.
The best idea we observed was the use of a single gauge that
was adapted to fit in an air line quick connection. The
operator simply inserted the gauge into quick connections
that were mounted in key locations on the air system
piping.
Accuracy is critical when comparing readings and trying to
isolate a problem. It's important that you use a
high-quality gauge.
Mistake 10: Cookie-cutter
approach to oil and filter changes
A preventive maintenance program is essential for maximizing
the service life of a compressor. The key is to make sure
your program matches your application.
This means monitoring filter and lubricant condition by
measuring pressure drop and by using a regular oil analysis.
This will help you create a schedule for change intervals
that will provide the best protection for your compressor.
a) Oil analysis can be a helpful tool for compressor
diagnostics. Quarterly samples of the oil appear to be more
than adequate to keep an eye on normal wear.
b) The best way to determine when to change your inlet air
filters is to measure the restriction in the piping between
the filter and the intake of the compressor. This
restriction can be monitored by a water manometer, an
intake
filter indicator or a dial gauge that is calibrated in
inches of water.
The idea is to service the
filter when the monitor reaches a
certain level of restriction. This specification can vary
between 10 and 20 inches of water because of the different
designs of filters. We recommend that you get a guideline
from a filter vendor that is knowledgeable about
compressors.
A final thought Don't rely solely on the advice of
equipment vendors when
considering making improvements to your compressed air
supply. Get a second opinion.
Want to talk to an
independent consultant that does not sell
equipment? If so, send an email to advice@compressorwise.com
with your
question. We will refer you to a specialist that can handle
your
request. Be sure to include your phone number and the best
time to reach you.
Dan Wise is the Webmaster
for CompressorWise.com, a Web site dedicated to
helping industry with information about how to get the most from compressors
and compressed air systems. For more information, visit
www.CompressorWise.com.
Back to top
Back to Web-exclusive articles
archives
|